9100c NXT Anaesthesia Machine

The anesthesia workstation that gives you peace of mind

 

1800-102-2977

9100c NXT Banner Updated 20201015

9100c NXT is a precise anaesthesia solution that gives you peace of mind by supporting an easy and trustful anaesthesia delivery experience

Enables you to effectively deliver anesthesia and ensure seamless recovery

  • Deliver anesthesia precisely
  • Dual flow sensors for precise volume and pressure delivery to reduce the challenges in managing neonatal and pediatric patients
  • Avoid commonly occurring unsafe conditions during general anesthesia
  • Deliver low flow anesthesia (<1L/min fresh gas flow) with confidence - for early patient recovery
  • Precise delivery of Tidal Volume (TV) and Anesthetic Agent (AA)
  • Small internal volume of 2.6L and non-decoupled fresh gas delivery resulting faster gas kinetics, strike off after delivery.
9100 nxt s-curve 1

Scalable across a wide range of patient groups and surgical procedures

  • Treat neonates to adult patients
  • TV delivery as low as 5ml in pressure control ventilation and as low as 20ml in volume control ventilation
  • Delivers sustained target pressure with decelerating flow that adapts to patient’s respiratory mechanics allowing improved alveolar gas exchange and enhanced oxygenation
  • Spirometry, with ability to save and compare reference loops for continuous monitoring of ventilatory status
  • EZChange CO2 bypass system enables removal of the absorbent canister from the patient circuit without introducing leaks into the breathing system, especially required during long duration surgeries
  • Availability of SIMV, PSVPro™ with apnea backup
  • ICU quality ventilator with ultra-sensitive trigger to detect breathing effort of even an infant patient.
9100 nxt s-curve 2

Based on GE/Datex Ohmeda’s 100+ years legacy of innovation and trust

  • >100,000 units sold and trusted by clinicians across the world
  • Shares the same reliable parts used in GE/Datex-Ohmeda anesthesia workstations such as AISYS CS2, Avance CS2 and Aestiva
  • Ease of operation as it employs well-known Datex Ohmeda workflows, screen prompts and tip messages, audio alarms, simple one step bag-to-vent switch and direct access to ventilator parameter screen
  • Pre-use machine directed checks including the vaporizer leak test that prepare the device for patient use in <5 minutes
  • 9100c NXT is also available in a two gas variant.
9100 nxt s-curve 3

Related Products

Vaporizers and Cassettes

Deliver with confidence. Anesthesia vaporizers and cassettes from GE Healthcare are developed for delivery accuracy under a wide range of conditions. With the Aladin cassettes as well as the mechanical Tec 6 Plus and Tec 7 Selectatec vaporizers, we offer accuracy, ease of use, and low cost of ownership.
Anaesthesia image hero

Centricity™ High Acuity Anesthesia

Centricity™ High Acuity Anesthesia is an integrated anaesthesia management solution that enables improved quality of patient care from peroperative assessment, through induction and operating room to post-anaesthesia care.

Supporting Materials

Vaporizer brochure 820
Vaporizer brochure 850
Disclaimer
The official name of the product is 9100c NXT, authorized by Wipro GE HealthCare Pvt. Ltd., located at No. 4, Kadugodi Industrial Area, Whitefield, Bangalore, Karnataka – 560067. The system is intended for use by trained healthcare professionals familiar with anesthesia workflows and ventilatory management. For safe and effective operation, users must verify system calibration, ensure correct gas supply connections, and confirm ventilator and agent settings appropriate to the patient’s clinical condition. Continuous monitoring of patient vitals and system performance is essential throughout the procedure. This system must not be used in environments containing explosive gases or on patients with contraindications to general anesthesia. Operators must follow all institutional protocols, manufacturer instructions, and established clinical guidelines. This material was created and reviewed on 22 December 2025, and additional product and safety information is available upon request.
Contact Us

We're ready to support you in your moments that matter. For service assistance, call us.

Thank you!

We received your request for assistance.

A GE Healthcare specialist will be reaching out shortly.

Something went wrong

We will check and get back.

JB00375FR