• Change country/language

    Looks like you’re in {} — you’re on the {} site.

    Cancel

    Country and language selected

    You are being redirected to the {} site. Products and services availability vary by country. Do you wish to continue?

    Continue
    Cancel

CASE Cardiac Assessment System for Exercise Testing

CASE Cardiac Assessment System for Exercise Testing

The CASE™ Cardiac Assessment System for Exercise Testing supports detection and effective management of Cardiovascular Disease (CVD).

BROADER MEASUREMENTS.
Broader measurements.

The CASE™ Cardiac Assessment System for Exercise Testing supports detection and effective management of Cardiovascular Disease (CVD). It provides clinicians with a suite of comprehensive diagnostic measurements, offering deeper insights and broader perspective on cardiac patient management.

We added measurements, not complexity

We added measurements, not complexity

 

Known for robust ECG signal quality and clinical accuracy, the CASE system also provides a suite of advanced measurements to help you manage a variety of CVD patient groups.

  • Coronary artery disease (CAD) – CASE is the only stress solution to use ST/HR Hysteresis analysis, shown to improve the accuracy of CAD detection. 2
  • Sudden cardiac death – The CASE system provides critical algorithms – including the patented T-wave Alternans (TWA) algorithm – to assist you in predicting patients at risk of sudden cardiac death.
  • Cardiovascular disease monitoring – Metabolic equivalent (METS) level achieved during exercise testing is an important predictor of adverse cardiac events after myocardial infarction. 3 Failure to achieve 5 METS during treadmill exercise is associated with a worse prognosis. 4

2 R.Lehtinen, H.Sievänen, J.Viik, V.Turjanmaa, K Niemelä and J.Malmivuo. Accurate Detection of Coronary Artery Disease by Integrated Analysis of the ST-Segment Depression/Heart Rate Patterns During Exercise and Recovery Phases of the Exercise Electrocardiography Test. Am J Cardiol 1996; 78:1002–10062 AHA Releases 2015
3 Myers, J., et al., Exercise capacity and mortality among men referred for exercise testing. The New England Journal of Medicine, 2002. 346(11): p. 793-801.
4 D.J.Mertens et.al, A simple formula for the estimation of maximal oxygen intake during cycle ergometry. European Heart Journal (1994) 15, 1247–1251.

Quick, easy-to-read results

 

The CASE exercise testing system enables a fast, confident assessment. The results are displayed in a quick and easy to read format offering you a broad insight into your patients’ response to exercise testing.

 

 

  • In-test access to results – Access to in-test full disclosure means you can deep dive into any element of the ECG at any time during the test.
 
  • XTI algorithm – Highlights measurement deviations, providing an advanced analysis of patients’ functional response, cardiac risk profile and coronary artery disease risk.
BROADER TESTING FLEXIBILITY.

Broader testing flexibility.

 

The more testing devices and modalities you can integrate with your cardiac assessment system, the more flexibility you have in choosing the right combination for each patient.

 

Not all accessories shown below are available in all markets.

 

 

Comfortable and scalable

 

Wireless acquisition (with optional GEH-ECG-1200) eliminates the need for cumbersome wires so patients can enjoy untethered movement during testing. CardioSoft Client added to a network PC creates a Multi-modality cardiac review workstation.

 

 

Blood Pressure: Accurate, hands-free monitoring

 

With the SunTech® Tango® M2 automated blood pressure monitor, you can focus on your patient during stress testing rather than spending time taking manual measurements.

 

 

Ergometry: Have it your way

 

The CASE system integrates with both upright and supine eBike ergometers, as well as T2100 series treadmills. GE Healthcare ergometry devices are known for reliability, robust engineering, and easy access for all body types.

 

 

Imaging Studies: Trusted leadership technology

 

The CASE system easily integrates with imaging technologies, including stress echocardiography and nuclear imaging, to help you evaluate a wide range of heart conditions.

 

 

 

 

 

 

 

BROADER INTEROPERABILITY. BETTER WORKFLOW
Broader interoperability. Better workflow.

Cardiac testing is increasingly complex and interoperability with your enterprise systems is critical. The ability to connect CASE to your network gives you more workflow options.

CASE Integration

 

Maintaining patient data security

 

Protecting your system against malware and other attacks is one part of system security, but is also critical to protect the patient information stored in that system.

Maintaining patient data security
ECG

Scalable and flexible.

 

Whatever the size of your facility, your stress solution can be configured to maximize productivity and simplify workflow based on your IT and clinical needs. CASE can seamlessly integrate to MUSETM, and PACS systems so results are available virtually anywhere, anytime. Clinical analysis data, report results, manual interpretations and confirmations are included, providing a comprehensive view of the patient’s diagnosis.

 

Advanced security and compliance. The CASE system protects your data and system with multi-level password login configurations.

 

Open system architecture. GE Healthcare uses industry standard communication protocols, including DICOM and XML.

 

Support services. Count on GE Healthcare technical support experts to provide installation, system configuration, upgrade services and remote support.

JB00592AFG May 2023