• Change country/language

    Looks like you’re in {} — you’re on the {} site.

    Cancel

    Country and language selected

    You are being redirected to the {} site. Products and services availability vary by country. Do you wish to continue?

    Continue
    Cancel
Critical Care Suite 2.0* On-device artificial intelligence for X-ray. Helping you when every minute counts.

Critical Care Suite is a collection of AI algorithms embedded on X-ray systems for automated measurements, case prioritization and quality control.

aiportal510k

GE Healthcare X-ray
AI Portal

 

Test drive the Critical Care Suite on the GE X-ray AI Portal. Upload chest X-ray images and experience the artificial intelligence algorithms online.

Endotracheal Tube Positioning*

 

As many as 25% of intubations outside of the operating room result in mispositioned ET Tubes, which can lead to severe complications2-6.

 

Critical Care Suite’s Endotracheal Tube Positioning AI algorithm is now available on AMX 240 mobile X-ray systems.

Pneumothorax Triage and Notification

 

 

On-device AI solution that can help triage critical conditions, such as pneumothorax, alleviating the overwhelming demand that urgent X-rays are placing on radiology teams.



The Pneumothorax Notification is included in Critical Care Suite 2.0 and is available on AMX 240 mobile X-ray systems as well as Definium™ 656 HD and Definium 646 HD fixed X-ray systems.

Quality Care Suite

 

Quality Care Suite includes AI algorithms that operate in parallel and help technologists reduce image quality errors and improve efficiency.



Quality Care Suite algorithms are included in Critical Care Suite 2.0 and is available on AMX 240 mobile X-ray systems as well as Definium 656 HD and Definium 646 HD fixed X-ray systems

critica-care-suite-case-study-mask-465x465-graphics-rad-

COVID-19 Case Study

Critical Care Suite enables expedited treatment of a spontaneous pneumothorax in an intubated COVID-19 patient

REFERENCES

 

*510(k) pending. Distributed in accordance with FDA imaging guidance regarding COVID19 public health emergency.

 

** The technologist notification is generated 15 mins after exam closure. It is contextual and does not provide any diagnostic information. The on-device, technologist notification is not intended to inform any clinical decision, prioritization, or action.

 

  1. Stephen E. Lapinsky. Endotracheal intubation in the ICU. Crit Care. 2015; 19(1): 258.

  2. Jemmett ME, Kendal KM, Fourre MW, Burton JH. Unrecognized misplacement of endotracheal tubes in a mixed urban to rural emergency medical services setting. Acad Emerg Med 2003;10:961–5.

  3. Katz SH, Falk JL. Misplaced endotracheal tubes by paramedics in an urban emergency medical services system. Ann Emerg Med 2001;37:32–7.

  4. Lotano R, Gerber D, Aseron C, Santarelli R, Pratter M. Utility of postintubation chest radiographs in the intensive care unit. Crit Care 2000;4:50–3.

  5. McGillicuddy DC, Babineau MR, Fisher J, Ban K, Sanchez LD. Is a postintubation chest radiograph necessary in the emergency department? Int J Emerg Med 2009;2:247–9.

  6. Rachh, Pratik, et al. “Reducing STAT Portable Chest Radiograph Turnaround Times: A Pilot Study.” Current problems in diagnostic radiology (2017).

  7. GE Healthcare Data on File

  8. FDA 510(k) K183182
Contact Us