Discovery Dimension

See. Discovery Dimension.

Discovery VCT includes our Discovery Dimension, the first fully integrated PET/CT operator's console for improved workflow, database management and image review. Now clinicians can process and review acquired data directly on the console, as well as manage, network and retrieve from a single patient database.

Whole Body FDG Scan and Myocardial Imaging




All in one

    See. All in one.
    Rad Rx – Capturing the full capability of CT with PET can be a workflow limitation. Rad Rx offers the ability to acquire a CT scan using the same parameters or technique used in a radiology prescription. The same CT scan can be used for attenuation correction with no need to acquire separate scans.

  • Workflow optimization with simultaneous acquisition of attenuation correction CT and radiology prescription CT
  • Multiple series, multiple groups acquisition capability; any combination of helical, cine, axial
  • Eliminate "banana" artifact by using cine CT acquistion for CTAC


Flexibility

    See. Flexibility.
    VUE Point Reconstruction – Optimal image quality in multiple acquisition modes has always been a priority. VUE Point intelligent reconstruction technology, a GE exclusive, provides a higher signal-to-noise ratio (SNR) and the flexibility of outstanding image quality for all patient types in both 2D and 3D modes.

  • Exceptional image quality in any mode
  • Images available in real-time while you scan
  • Improved quanitative accuracy


Motion

    See. Motion.
    4Dx – No longer will you need to bring your patients back for a gated study. 4Dx puts motion to work for you, enabling gated and static acquisition in the same scan for enhanced visualization and management in areas of interest subject to motion.

  • Simultaneous dynamic (gated) and static acquisition
  • Multiple dynamic axial fields of view in the same study
  • View full extent of tumor motion for advanced radiation treatment planning


True cardiac alignment
With ACQC, the operator is able to properly align the PET and CT image data sets together.
    See. True cardiac alignment.
    ACQC – Now you have the ability to eliminate cardiac PET/CT misregistration. Attenuation Correction Quality Control (ACQC) ensures true cardiac PET and CTAC image fusion alignment. This tool can help determine the shift vector required to correct misalignment between the PET and CTAC data.

  • Properly align PET and CT image data sets together
  • Save the shift information to use in retrospective reconstruction
  • Flexibility to use any CT data set from the series