eFlexTrial Options
|

MR-Echo (Realtime Cardiac MR Imaging) offers the contrast of MR combined with real-time speed and interaction approaching echocardiography.
|
|

Propeller Suite
Propeller (Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction) can’t miss technique provides diagnostic exams by reducing motion in complex neurological imaging.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

3D Flair
3D Flair (Fluid Attenuation Inversion Recovery) provides FLAIR-weighted contrast in a 3-dimensional, isotropic acquisition.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

Fluoro-Triggered MR Angiography Never miss a contrast bolus again. Fluoro-Triggered MRA gives the Radiologist or Technologist the ability to image the vascular anatomy of interest in real time and to see the arrival of the contrast bolus and almost instantly start the acquisition of a high resolution MRA exam.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

Diffusion Tensor Imaging extends the capablities of Diffusion Weighted imaging. Tensor imaging acquires from 6 to 55 orientations to differentiate tissue based on the degree of diffusion anisotrophy. Automated online processing produces image maps based on T2-weighted combined, ADC and fractional anisotropy.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

Spiral High Resolution Imaging & Real Time Spiral Imaging The Spiral Imaging sequence was designed specifically for imaging the Coronary Arteries. Spiral pulse sequences use a very efficient Spiral K-Space Trajectory to acquire high resolution images of cardiac anatomy.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

Advanced Cardiac Imaging with 2D FIESTA Cine The FIESTA 2D CINE pulse sequence provides excellent blood to myocardium contrast for gated cardiac imaging. The short TR/TE capability of this sequence allows acquisition of high quality cardiac images that are less sensitive to turbulent blood flow.
|
|
Dr. Oliver Strohm, M.D. and Dr. Thoralf Niendorf, Ph.D.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

FastCine w/Tagging
is a gated fast gradient echo technique used for cardiac imaging. FastCine is a white-blood technique with excellent blood myocardium contrast and full cardiac cycle coverage.
Please confirm that your system has ALL
the required prerequisites for this software application.
|
|

3D Myocardial Evaluation is a myocardial assessment tool that uses VAST (Variable Sampling in Time) technology to enable whole heart coverage in a single breath-hold. Myocardial evaluation uses an adjustable IR pulse for optimize signal from the myocardium in breath-hold scans times (per slice.) In addition using a superior echo train technology and exclusive notched saturation pulse yields excellent time course exams.
Please confirm that your system has ALL
the required prerequisites for this software application.
|
|

3D FatSat FIESTA provides robust coronary artery imaging in a short breath-hold. The software acquires 3D images using FIESTA (Fast Imaging Employing Steady-state Acquisition).Fat suppression is applied to accentuate the coronary arteries.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

VIBRANT (Volume Image Breast Assessment) provides simultaneous bilateral breast imaging in the sagittal plane. VIBRANT
uses the 3dfgre sequence and ASSET in the slice direction to acquire sagittal slices from both breasts without doubling scan time or interpolating of data. This technique utilizes dual shimming , optimized fat suppression and automated on-line subtraction for ultimate background suppression. VIBRANT technique involves one visit, one injection, both breasts with no compromises.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|
eFlexTrial Options
Lava-XV
Please confirm that your system has ALL the required prerequisites for this software application.
Please call GEMS Direct at 800-886-0815 or e-mail at gemsdirect@med.ge.com for further assistance.
|
3D Cosmic
Please confirm that your system has ALL the required prerequisites for this software application.
Please call GEMS Direct at 800-886-0815 or e-mail at gemsdirect@med.ge.com for further assistance.
|
BrainWave PA
Please confirm that your system has ALL the required prerequisites for this software application.
Please call GEMS Direct at 800-886-0815 or e-mail at gemsdirect@med.ge.com for further assistance.
|
BrainWave RT
Please confirm that your system has ALL the required prerequisites for this software application.
Please call GEMS Direct at 800-886-0815 or e-mail at gemsdirect@med.ge.com for further assistance.
|
Breast Single Voxel Spectroscopy
Please confirm that your system has ALL the required prerequisites for this software application.
Please call GEMS Direct at 800-886-0815 or e-mail at gemsdirect@med.ge.com for further assistance.
|
T2 Mapping
Please confirm that your system has ALL the required prerequisites for this software application.
Please call GEMS Direct at 800-886-0815 or e-mail at gemsdirect@med.ge.com for further assistance.
|
|

2D FatSat FIESTA (Fast Imaging Employing Steady-state Acquisition) is designed to produce high SNR images extremely rapidly with unique contrast between tissues.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

Probe 3D CSI
The Probe 3D CSI Upgrade expands the capabilities of the existing Probe2000 Package to include 3D Multi-Voxel Proton acquisitions.
|
|

Fast Gradient Echo-Echo Train Imaging (FGRET) & Fast Gradient Echo-ET Real Time Imaging The Fast Gradient Echo-Echo Train pulse sequence provides dynamic high temporal and spatial resolution images of the myocardium that are ideally suited for the evaluation of myocardium.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

Diffusion Weighted EPI is a single-shot echo planar imaging technique that uses 3 directional motion sensing gradient pulses to differentiate tissue based on the diffusion motion of water, and is typically used to enhance the ability of MR to detect acute and hyperacute cerebral infarct.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

High Resolution Imaging with 3D FIESTA The FIESTA 3D pulse sequence provides excellent high-resolution images of fluid filled structures in very rapid acquisition times. FIESTA employs Ultra Short TR's and TE's for with very fast scan times with outstanding image contrast.
|
|
Dr. Andreas Hueck, M.D. and Hubert Lejay
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

High Resolution Imaging with 3D FIESTA-C
High Resolution Imaging with 3D FIESTA-C pulse sequences is an advanced software package, which provides excellent high-resolution images of fluid filled structures in very rapid acquisition time. FIESTA-C (Fast Imaging Employing Steady-state Acquisition uses an extremely short (TR) between RF pulses such that high-resolution 3D volume images can be acquired rapidly. FIESTA-C employs a special phase-cycling technique and steady state contrast mechanisms to provide high SNR images with strong signal from fluid while effectively suppressing background tissue.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

3D Cardiac Navigator
The Cardiac Navigator feature combines a cardiac gated, 3D Fast GRE or 3D FIESTA sequence with a navigator pulse that tracks the motion of the diaphragm. By placing the navigator tracker pulse over the right hemi-diaphragm, the acquisition is synchronized to the end-expiration respiratory phase of the patient thus minimizing respiratory ghosting artifacts.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

Probe and Probe 3D CSI
The Probe 3D CSI Software is an addition to the Probe2000 Package that enables 3D Multi-Voxel Proton Spectroscopy. This 3D capability adds Whole Brain coverage to Signa's spectroscopic imaging capabilities.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|

TRICKS uses an intricate temporal sampling and complex data recombination to accelerate temporal resolution without sacrificing SNR or spatial resolution. This technique eliminates the need for test injections of contrast or triggering. The Radiologist or Technologist just injects and scans.
Please confirm that your system has ALL the required prerequisites for this software application.
|
|